- Transit Drop - Operating
- 4' (1.22 m; drop direct to concrete) - 7' ((2.134 m: plywood over concrete) - 26 total drops: one drop to each face, edge and corner - Unit is operating and remains operational- Exceeds MIL-STD-810G, Method 516.6, Proc IV
- Minimum Integrity Vibration
- Minimum Integrity testing - Unit is not operating - MIL-STD-810G, Method 514.6, Procedure I: Figure 514.6 E-1, Category 24
- Vehicle Vibration
- Vehicle vibration testing - Unit is operating - MIL-STD-810G, US Highway Truck, Method 514.6, Procedure I: Figure 514.6 C-1 Category 4- Tablet with xDock and Vehicle Kit
- Temperature Extremes (Operating/Non-Operating)
- Operating: -34° F to 140° F (-37° C to 60° C): Cold boot within 15 min (power source). - Non-Operating/Storage: -60° F to 160 °F (-51°C to 71°C). - MIL-STD-810G, Methods 501.5, 502.5, Procedures I and II.
- Thermal Shock
- 60° F to 160° F (-51° C to 71° C) - MIL-STD-810G Method 503.5, Procedure II, cyclic - Unit is not operating
- Blowing Rain
- 4.0 in/hr (101.6 mm/hr) of blowing rain, 40-mph wind source for 30 minutes on each surface - Unit is operating - MIL-STD-810G, Method 506.5, Procedure I
- Blowing Sand & Dust
- Blowing sand and dust at 30-mph for 30 minutes - Unit is operating - MIL-STD-810G, Method 510.5, Procedures I (Blowing Dust) and II (Blowing Sand)
- Humidity
- 3%-95% - Non-condensing humidity - Five 48-hour cycles - Unit is operating - MIL-STD-810G, Method 507.5, Procedure II
- Salt Fog Spray
- 5% Saline exposure for 2 Cycles x 48 hrs - (24hrs wet/24hrs dry) - Unit is not operating - MIL-STD-810G, Method 509.5, Procedure I
- Functional Shock
- 40g (peak), 11 ms, saw-tooth, 3 axis x 6 shocks = 18 shocks - Unit is not operating - 20g (peak) operating
- MIL-STD-810G, Method 516.6, Procedure I
- Crash Shock
- 75g (peak), 11ms, saw tooth, 2+/- shocks x 3 axis = 6 shocks - Unit is not operating - MIL-STD-810G, Method 516.6, Procedure V
- Bench Shock (M5)
- 4" (101.6mm) drop onto wooden bench, Four drops on each face- Unit is not operating - MIL-STD-810G, Method 516.6, Procedure VI
- Altitude
- Chamber at 50,000 ft for 1 hour -Unit is operating - MIL-STD-810G, Method 500.5, Procedure II
- Contamination by Fluids
- Detergents, brake fluid, aromatic hydrocarbons - Unit is not operating - MIL-STD-810G, Method 504.1
- Fungus
- 28 days; US Fungus Types - No growth. Unit is not operating - MIL-STD-810G, Method 508.6, Procedure I
- Solar Radiation
- Steady State A1. 1120 W/m2 (355 Btu/ft2/hr) UVB @ 500 C, 7 x2 4hr cycles - Unit is not operating - MIL-STD-810G, Method 505.5-2, Procedure II